// Guide

Will a chamber fit
in my space?

Before you look at models, look at the room. Hyperbaric chamber size varies a lot from one model to the next, so move the two sliders to your room's clear dimensions and you'll see instantly which chambers fit, access zone included.

6 models checkedAccess zone includedRotated layout checked too

// What to measure

Three measurements and a door.

To know whether a chamber fits, you need the room's clear width and depth, plus the ceiling height. Clear means not counting radiators, columns, protruding baseboards or the swing of a door that opens into the room.

The entry door matters less than you might think: our chambers are modular and the parts pass through openings of at least 31 in (80 cm), so the chamber is assembled inside the room. What can't be solved is a room that is too small, and the checker below tells you that in ten seconds.

// Fit checker

Measure your room. We'll show you what fits.

Set your room's clear width and depth. We automatically add a 1.8 ft (0.55 m) access zone around the chamber and also test the chamber rotated 90°.

10 ft (3.20 m)
13 ft (4.00 m)

Room area: 138 ft² (12.80 m²)

Measure the real clear space: leave out radiators, doors that open into the room and columns.

Result

    A rough estimate for planning. The modular parts pass through doors at least 31 in (80 cm) wide and the chamber is assembled inside the room, so a narrow door is rarely an obstacle. The final location is always confirmed in the technical site survey, on your floor plan. The Biruni (12+2 seats) isn't listed here because each installation is designed case by case.

    // Beyond the floor

    Three more things we check.

    01

    Ceiling height

    The walk-in Kagan stands 79 in (200 cm) tall; the Cezeri is just 35 in (90 cm). Also check the clear height under beams, ducts or pendant lights.

    02

    Floor load capacity

    Weights range from 573 lb (260 kg) to more than 2,425 lb (1,100 kg) depending on the model. On upper floors and in renovations, we check the allowable load before confirming the location.

    03

    Power and ventilation

    A standard dedicated circuit, with no plumbing or construction work. Room ventilation is assessed during the site survey, along with the access route.

    // Next step

    Confirm it on your floor plan.

    The checker gives you a first answer in seconds; the site survey confirms it. Send us your measurements or floor plan and we'll tell you for certain what fits and where to place it.

    Oxyliving chambers are designed for general well-being and recovery. They are not presented as a treatment, cure or diagnosis for any medical condition. Our CE marking covers wellness use.